Mechanical feedback: the float valve
Open the interactive version →FEEDBACK LOOPS
Feedback doesn't need electronics. In a toilet cistern a float rises with the water and closes the valve, so the tank always refills to the same level.
Full: the float has closed the valve
How it works
- When the cistern is flushed the water level drops and the float falls with it.
- The float arm is a lever: as it drops it opens the inlet valve and water flows in.
- As the water rises the float rises, pushing the valve shut. The level itself is the feedback.
- Bending or adjusting the float arm changes the level at which the valve closes (the set point).
- Other mechanical closed loops: the bimetal strip in a kettle or iron, and Watt's centrifugal governor on steam engines.
Examples
- Toilet cistern
- Water tank in a loft
- Livestock drinking trough
- Carburettor float bowl
See also
Open and closed loop
Check your understanding
What is the sensor in a float valve?
The float, which senses the water level.
Is a float valve open or closed loop? Why?
Closed loop: the water level feeds back through the float to close the valve.
Printable worksheet
An A4 sheet to print or save as a PDF: a blank diagram to label, a gap-fill and check questions. There is also an EAL support version. The diagram is made from the view above, so set it up first.